Welcome to the official website of Guangzhou Shuntai Quality technical Service Co., Ltd!

  EN

Laboratory Center

Electromagnetic compatibility testing

SQT Electromagnetic Compatibility Testing Center has a complete EMC testing system for automotive electronics, which can meet the testing requirements of domestic, international, European and American standards, enterprise standards, etc. It can provide professional and efficient EMC R&D design, rectification and consulting services, and help customers quickly overcome EMC design difficulties and successfully pass the testing and certification.

It has 3 car semi anechoic chambers and 1 electromagnetic shielding room

Laboratory equipment capacity

2 sets of radiation conduction test systems

1 set of radiation immunity test system

1 set of radar wave immunity test system

1 set of hand-held antenna immunity test system

2 sets of BCI immunity test system

1 set of low-frequency magnetic field immunity test system

1 set of low frequency magnetic field emission test system

1 set of electrostatic test equipment

1 set of lightning surge and fast burst test system

1 set of power frequency magnetic field test system (construction machinery vehicle)

1 set of transient pulse immunity and emission test system

......

Test items and standards can be met:

EMC electromagnetic compatibility test

Test items

Test standards

Test capability

Electromagnetic emission test

 

 

 

Radiation emission

CISPR25:2016

GB/T18655:2018

ECE R10.06 、ECER116.00 、ISO13766、ISO14982

Test standard of main engine factory

CISPR25 Background Noise: Class 5

    Frequency Range: 10Hz to 7GHZ

    Max Power Supply: DC 1000V/200A

Transient conducted emission

ISO7637-2:2004ISO7637-2:2011

GB/T21437-2:2008

Test standard of main engine factory

      DC:12/24V, 30A

Conducted emission

Conducted Emission

(Voltage Method)

CISPR25:2016EN55025:2017、GB/T18655:2018

Test standard of main engine factory

CISPR25 Background Noise: Class 5

Frequency Range: 0.1KHZ to 110MHZ

Max Power Supply: DC 1000V/200A

Low frequency magnetic field radiation emission

MIL-STD-461G

Test standard of main engine factory

  10Hz-250KHz

Electromagnetic immunity test

 

 

 

 

 

 

High current injection

ISO11452-4:2020

GB/T33014.4:2016

Test standard of main engine factory

Frequency Range: 10kHz~1000MHz

Max Current: 500mA  (Substitution)

         300mA  (Closed loop)

Transient conducted immunity


 

Transient Conducted Immunity

(Supply line)

ISO7637-2:2004

ISO7637-2:2011、GB/T21437-2:2008

Test standard of main engine factory

Pulse 1 , Pulse 2a, Pulse 2b, Pulse 3a, Pulse 3b, Pulse 4, Pulse 5a, Pulse 5b

Transient Conducted Immunity(other than Mains)

ISO7637-3

ISO7637-2

GB/T21437-2

Test standard of main engine factory

Test method : CCC, ICC, DCC

Electrostatic immunity test

ISO10605:2008

GB/T19951:2019

Test standard of main engine factory

Max Voltage: 30kV 

CR Value: 150pF/ 330Ω, 150pF/ 2000Ω,

330pF/ 330Ω, 330pF/2000Ω

Radiated immunity

(ALSE method)

ISO11452-2:2019

GB/T33014.2:2016

Test standard of main engine factory

80MHz~200MHz : 100V/m

200MHz~1000MHz :200V/m

1000MHz~6000MHz :300V/m

Low frequency magnetic field immunity

ISO11452-8

Test standard of main engine factory

DC 3000A/m,

15Hz-150KHz

Handheld emission immunity

ISO11452-8

Test standard of main engine factory

26MHz-6GHz

Electrical performance test

ISO 16750-2:2012

GB/T28046-2:2019

Test standard of main engine factory

DC power supply, overvoltage
Superimposed AC voltage
Slow rise and slow drop of supply voltage
Instantaneous drop of supply voltage
Reset characteristic, start characteristic
Load shedding, reverse voltage
Reference grounding and power supply offset
Open circuit test, voltage withstand and insulation resistance

.......